{"id":170,"date":"2021-11-04T10:26:18","date_gmt":"2021-11-04T01:26:18","guid":{"rendered":"https:\/\/ev-coms.com\/?page_id=170"},"modified":"2022-01-31T18:39:37","modified_gmt":"2022-01-31T09:39:37","slug":"p101","status":"publish","type":"page","link":"https:\/\/emt-japan.com\/english\/?page_id=170","title":{"rendered":"Automatic Analytical Instruments for On-site \/ Off-site"},"content":{"rendered":"<h5 class=\"style5b\">Automatic Analytical Instruments for On-site \/ Off-site<\/h5>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff11 --><\/p>\n<h4 class=\"style5a\"><strong>Compact Analyzer \/ Mark\u2161<\/strong><\/h4>\n<p><!-- \u30b3\u30f3\u30c6\u30f3\u30c4\u3000--><\/p>\n<div class=\"post_content2 clearfix\">\n<div class=\"post_row2\">\n<div class=\"post_col2 post_col2-2a\">\n<img decoding=\"async\" src=\"\/images\/20211110\/1.png\" width=\"100%\">\n<\/div>\n<div class=\"post_col2 post_col2-2b\">\n<div class=\"fqbun\">\n<ul>\n<li>For replacing manual analysis at labs either on-site or off-site.\n<li>For limited space.\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fqbun\">\n<table class=\"col-head-type1\">\n<tr>\n<th>Installation<\/th>\n<td>Recommend within 10m form tank if installed on-site<\/td>\n<\/tr>\n<tr>\n<th>Sampling capacity<\/th>\n<td>0.02ml &#8211; 10ml<\/td>\n<\/tr>\n<tr>\n<th>Analysis items<\/th>\n<td>Depend on manual analysis methods such as Neutralisation titration, Potentiometry, Colourimetry, absorbance, and chelating titration.<\/td>\n<\/tr>\n<tr>\n<th>Operating cycles<\/th>\n<td>Sampling &#8211; Analise &#8211; Calculate supply amount &#8211; Output signal for replenish<\/td>\n<\/tr>\n<tr>\n<th>Analysis time<\/th>\n<td>15 &#8211; 30 min.<\/td>\n<\/tr>\n<tr>\n<th>SPC (Statistical Process Control)<\/th>\n<td>Able to manage\/edit Excel data and trend graphs<\/td>\n<\/tr>\n<tr>\n<th>Languages<\/th>\n<td>Korean, English, Chinese, Japanese<\/td>\n<\/tr>\n<tr>\n<th>Printing method<\/th>\n<td>Thermal printer<\/td>\n<\/tr>\n<tr>\n<th>Communications ports<\/th>\n<td>RS485<\/td>\n<\/tr>\n<tr>\n<th>Analysis accuracy<\/th>\n<td>+\/- 2% &#8211; 4%<\/td>\n<\/tr>\n<tr>\n<th>Dimensions<\/th>\n<td>W 300 x D 200 x H 250 (mm)<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>5.5kg<\/td>\n<\/tr>\n<tr>\n<th>Power supply<\/th>\n<td>AC110V\/220V<\/td>\n<\/tr>\n<tr>\n<th>Maintenance<\/th>\n<td>Annual service is recommended (service interval may vary by operation frequency).<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><!-- \u30b3\u30f3\u30c6\u30f3\u30c4\u3000--><\/p>\n<h4 class=\"style5a\"><strong>ATCS (All round Titration and Control System)<\/strong><\/h4>\n<p><!-- \u30b3\u30f3\u30c6\u30f3\u30c4\u3000--><\/p>\n<div class=\"post_content2 clearfix\">\n<div class=\"post_row2\">\n<div class=\"post_col2 post_col2-2a\">\n<img decoding=\"async\" src=\"\/images\/20211110\/2.png\" width=\"100%\">\n<\/div>\n<div class=\"post_col2 post_col2-2b\">\n<div class=\"fqbun\">\n<ul>\n<li>Can be installed next to a tank that needs to be controlled and monitor its trends onsite.\n<li>Able to analyse up to four tanks.\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fqbun\">\n<table class=\"col-head-type1\">\n<tr>\n<th>Installation<\/th>\n<td>Recommend within 20m form tank (may vary by fluid type)<\/td>\n<\/tr>\n<tr>\n<th>Sampling capacity<\/th>\n<td>0.02ml &#8211; 10ml<\/td>\n<\/tr>\n<tr>\n<th>Analysis items<\/th>\n<td>Depend on manual analysis methods such as Neutralisation titration, Potentiometry, Colourimetry, absorbance, and chelating titration.<\/td>\n<\/tr>\n<tr>\n<th>Operating cycles<\/th>\n<td>Sampling \u2013 Analise \u2013 Calculate supply amount \u2013 Output signal for replenish<\/td>\n<\/tr>\n<tr>\n<th>Analysis time<\/th>\n<td>15 &#8211; 30 min.<\/td>\n<\/tr>\n<tr>\n<th>SPC (Statistical Process Control)<\/th>\n<td>Able to manage\/edit Excel data and trend graphs<\/td>\n<\/tr>\n<tr>\n<th>Languages<\/th>\n<td>Korean, English, Chinese, Japanese<\/td>\n<\/tr>\n<tr>\n<th>Printing method<\/th>\n<td>Thermal printer<\/td>\n<\/tr>\n<tr>\n<th>Communications ports<\/th>\n<td>RS485<\/td>\n<\/tr>\n<tr>\n<th>Analysis accuracy<\/th>\n<td>+\/- 2% &#8211; 4%<\/td>\n<\/tr>\n<tr>\n<th>Dimensions<\/th>\n<td>W 380 x D 370 x H 586 (mm)<\/td>\n<\/tr>\n<tr>\n<th>Rack for reagents<\/th>\n<td>W 380 x D 370 x H 1000 (mm)<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>25kg<\/td>\n<\/tr>\n<tr>\n<th>Power supply<\/th>\n<td>AC110V (Converter to 220V can be installed)<\/td>\n<\/tr>\n<tr>\n<th>Maintenance<\/th>\n<td>Annual service is recommended (service interval may vary by operation frequency).<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><!-- \u30b3\u30f3\u30c6\u30f3\u30c4\u3000--><!-- \u30d6\u30ed\u30c3\u30af\uff11 --><\/p>\n<h5 class=\"style5b\">Expected benefits from our automatic analytical instruments.<\/h5>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff12 --><\/p>\n<h4 class=\"style5a\"><strong>Cost Saving<\/strong><\/h4>\n<div class=\"fqbun\">\n<ul>\n<li>Necessary sampling amount is less than manual analysis, and thus less titrant is needed.\n<li>Contributes to reduce labour costs for conducting manual analysis.\n<li>By letting our instruments analyse chemicals automatically, you can allocate your work force for such as Kaizen activities and increasing production efficiency. This enables you to increase the effectiveness of other production processes.\n<\/ul>\n<\/div>\n<h4 class=\"style5a\"><strong>Quality<\/strong><\/h4>\n<div class=\"fqbun\">\n<ul>\n<li>High analytical accuracy (within +\/- 3%).\n<li>Real-time chemical management to prevent defective products from occurring.\n<li>Increasing production efficiency.\n<\/ul>\n<\/div>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff12 --><\/p>\n<h5 class=\"style5b\">Analysis mechanism<\/h5>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff13 --><\/p>\n<div class=\"post_content2 clearfix\">\n<div class=\"post_row2\">\n<div class=\"post_col2 post_col2-2\">\n<img decoding=\"async\" src=\"\/images\/20211110\/11b.png\" width=\"100%\">\n<\/div>\n<div class=\"post_col2 post_col2-2\">\n<img decoding=\"async\" src=\"\/images\/20211110\/12b.png\" width=\"100%\">\n<\/div>\n<\/div>\n<\/div>\n<div class=\"post_content2 clearfix\">\n<div class=\"post_row2\">\n<div class=\"post_col2 post_col2-2\">\n<img decoding=\"async\" src=\"\/images\/20211110\/13b.png\" width=\"100%\">\n<\/div>\n<div class=\"post_col2 post_col2-2\">\n<img decoding=\"async\" src=\"\/images\/20211110\/14b.png\" width=\"100%\">\n<\/div>\n<\/div>\n<\/div>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff13 --><\/p>\n<h5 class=\"style5b\">Monitoring trends (data transmission)<\/h5>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff14 --><\/p>\n<div class=\"post_content2 clearfix\">\n<div class=\"post_row2\">\n<div class=\"post_col2 post_col2-2a\">\n<img decoding=\"async\" src=\"\/images\/20211110\/21.png\" width=\"100%\">\n<\/div>\n<div class=\"post_col2 post_col2-2b\">\n<div class=\"fqbun\">\n<strong class=\"fq120\">It is a given that our instruments can analyse and refill our customers\u2019 chemicals.The important thing is that our customers can instantly understand the current status of production process.<\/strong><\/p>\n<ul>\n<li>Data of up to four tanks can be displayed by installing a specialised software.\n<li>Synchronise a control range of process to the PC and check the current status at any time by connecting our instrument to a PC (This improves awareness of your work force and plays an important role in appealing your quality control capability to your customers.)\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff14 --><\/p>\n<h5 class=\"style5b\">Examples<\/h5>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff15 --><\/p>\n<div class=\"fqbun\">\n<table class=\"col-head-type1\">\n<tr>\n<th>Examples<\/th>\n<td>Analysis items<\/td>\n<\/tr>\n<tr>\n<th>Developer&#8217;s solution (DRY FILM)<\/th>\n<td>Caustic Soda \/ RD dissolved amount \/ PH<\/td>\n<\/tr>\n<tr>\n<th>Electroless Copper Plating<\/th>\n<td>Caustic Soda \/ Copper \/ Formalin<\/td>\n<\/tr>\n<tr>\n<th>Electrolytic Copper Plating<\/th>\n<td>Sulfuric Acid \/ Copper \/ Chlorine<\/td>\n<\/tr>\n<tr>\n<th>Black Oxide<\/th>\n<td>Caustic Soda \/ Hydrogen Chloride<\/td>\n<\/tr>\n<tr>\n<th>Soft Etching<\/th>\n<td>Sulfuric Acid \/ Hydrogen Peroxide \/ Copper<\/td>\n<\/tr>\n<tr>\n<th>Electroless Nickel Plating<\/th>\n<td>Nickel \/ pH<\/td>\n<\/tr>\n<tr>\n<th>Electrolytic Nickel Plating<\/th>\n<td>Ni Sulfamate \/ Boric Acid \/ Ni Chloride \/ pH<\/td>\n<\/tr>\n<tr>\n<th>Acid Zinc Plating<\/th>\n<td>Ammonium Chloride \/ Zinc \/ pH<\/td>\n<\/tr>\n<tr>\n<th>Palladium Plating<\/th>\n<td>Palladium \/ pH<\/td>\n<\/tr>\n<tr>\n<th>Organic Acid Tin Plating<\/th>\n<td>Tin \/ Organic Acid<\/td>\n<\/tr>\n<tr>\n<th>Silver Cyanide Plating<\/th>\n<td>Silver \/ pH \/ Cyanide<\/td>\n<\/tr>\n<tr>\n<th>Cyanide Gold Plating<\/th>\n<td>Gold \/ pH \/ Cyanide<\/td>\n<\/tr>\n<tr>\n<th><span class=\"pc\">Examples<\/span><\/th>\n<td><span class=\"pc\">Analysis items<\/span><\/td>\n<\/tr>\n<tr>\n<th>Chrome plating<\/th>\n<td>Trivalent Chromium \/ Acidity<\/td>\n<\/tr>\n<tr>\n<th>Chemical Film Treatment<\/th>\n<td>Trivalent Chromium \/ Zinc<\/td>\n<\/tr>\n<tr>\n<th>Anodized Aluminium Plating<\/th>\n<td>Free concentration \/ Total concentration \/ Dissolved Aluminium<\/td>\n<\/tr>\n<tr>\n<th>Alkaline zinc plating<\/th>\n<td>Caustic Soda \/ Carbonated root \/ Zinc<\/td>\n<\/tr>\n<tr>\n<th>Reduction bath<\/th>\n<td>pH\/DMAB<\/td>\n<\/tr>\n<tr>\n<th>Blackening treatment<\/th>\n<td>Caustic Soda \/ Chlorine<\/td>\n<\/tr>\n<tr>\n<th>Pickling<\/th>\n<td>pH \/ Acidic components<\/td>\n<\/tr>\n<tr>\n<th>Pickling (iron)<\/th>\n<td>Acidic component \/ Bivalent iron<\/td>\n<\/tr>\n<tr>\n<th>Chemical treatment solution<\/th>\n<td>Total acid \/ Free acid \/ Accelerator<\/td>\n<\/tr>\n<tr>\n<th>Zirconium (Zr) coating<\/th>\n<td>Zr \/ pH<\/td>\n<\/tr>\n<tr>\n<th>Alkali degreasing<\/th>\n<td>Caustic Soda \/ pH<\/td>\n<\/tr>\n<tr>\n<th>Surface conditioning solution<\/th>\n<td>pH \/ TC<\/td>\n<\/tr>\n<\/table>\n<p><!--\n\n\n<table class=\"col-head-type1\">\n\n\n<tr>\n\n<th>Examples<\/th>\n\n\n\n<td>Analysis items<\/td>\n\n\n\n<th><span class=\"pc\">Examples<\/span><\/th>\n\n\n\n<td><span class=\"pc\">Analysis items<\/span><\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Developer's solution (DRY FILM)<\/th>\n\n\n\n<td>Caustic Soda \/ RD dissolved amount \/ PH<\/td>\n\n\n\n<th>Chrome plating<\/th>\n\n\n\n<td>Trivalent Chromium \/ Acidity<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Electroless Copper Plating<\/th>\n\n\n\n<td>Caustic Soda \/ Copper \/ Formalin<\/td>\n\n\n\n<th>Chemical Film Treatment<\/th>\n\n\n\n<td>Trivalent Chromium \/ Zinc<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Electrolytic Copper Plating<\/th>\n\n\n\n<td>Sulfuric Acid \/ Copper \/ Chlorine<\/td>\n\n\n\n<th>Anodized Aluminium Plating<\/th>\n\n\n\n<td>Free concentration \/ Total concentration \/ Dissolved Aluminium<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Black Oxide<\/th>\n\n\n\n<td>Caustic Soda \/ Hydrogen Chloride<\/td>\n\n\n\n<th>Alkaline zinc plating<\/th>\n\n\n\n<td>Caustic Soda \/ Carbonated root \/ Zinc<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Soft Etching<\/th>\n\n\n\n<td>Sulfuric Acid \/ Hydrogen Peroxide \/ Copper<\/td>\n\n\n\n<th>Reduction bath<\/th>\n\n\n\n<td>pH\/DMAB<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Electroless Nickel Plating<\/th>\n\n\n\n<td>Nickel \/ pH<\/td>\n\n\n\n<th>Blackening treatment<\/th>\n\n\n\n<td>Caustic Soda \/ Chlorine<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Electrolytic Nickel Plating<\/th>\n\n\n\n<td>Ni Sulfamate \/ Boric Acid \/ Ni Chloride \/ pH<\/td>\n\n\n\n<th>Pickling<\/th>\n\n\n\n<td>pH \/ Acidic components<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Acid Zinc Plating<\/th>\n\n\n\n<td>Ammonium Chloride \/ Zinc \/ pH<\/td>\n\n\n\n<th>Pickling (iron)<\/th>\n\n\n\n<td>Acidic component \/ Bivalent iron<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Palladium Plating<\/th>\n\n\n\n<td>Palladium \/ pH<\/td>\n\n\n\n<th>Chemical treatment solution<\/th>\n\n\n\n<td>Total acid \/ Free acid \/ Accelerator<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Organic Acid Tin Plating<\/th>\n\n\n\n<td>Tin \/ Organic Acid<\/td>\n\n\n\n<th>Zirconium (Zr) coating<\/th>\n\n\n\n<td>Zr \/ pH<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Silver Cyanide Plating<\/th>\n\n\n\n<td>Silver \/ pH \/ Cyanide<\/td>\n\n\n\n<th>Alkali degreasing<\/th>\n\n\n\n<td>Caustic Soda \/ pH<\/td>\n\n<\/tr>\n\n\n\n\n<tr>\n\n<th>Cyanide Gold Plating<\/th>\n\n\n\n<td>Gold \/ pH \/ Cyanide<\/td>\n\n\n\n<th>Surface conditioning solution<\/th>\n\n\n\n<td>pH \/ TC<\/td>\n\n<\/tr>\n\n\n<\/table>\n\n\n--><\/p>\n<\/div>\n<p><!-- \u30d6\u30ed\u30c3\u30af\uff15--><\/p>\n","protected":false},"excerpt":{"rendered":"Automatic Analytical Instruments for On-site \/ Off-site Compact Analyzer \/ Mark\u2161 For replacing manual analysis [&hellip;]","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":101,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-170","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/emt-japan.com\/english\/index.php?rest_route=\/wp\/v2\/pages\/170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/emt-japan.com\/english\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/emt-japan.com\/english\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/emt-japan.com\/english\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/emt-japan.com\/english\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=170"}],"version-history":[{"count":123,"href":"https:\/\/emt-japan.com\/english\/index.php?rest_route=\/wp\/v2\/pages\/170\/revisions"}],"predecessor-version":[{"id":441,"href":"https:\/\/emt-japan.com\/english\/index.php?rest_route=\/wp\/v2\/pages\/170\/revisions\/441"}],"wp:attachment":[{"href":"https:\/\/emt-japan.com\/english\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}